{"id":3808,"date":"2026-11-22T01:00:00","date_gmt":"2026-11-22T01:00:00","guid":{"rendered":"https:\/\/cpxzx.com\/"},"modified":"2026-09-22T06:49:44","modified_gmt":"2026-09-22T06:49:44","slug":"cf1200-cross-fluted-film-fill-2","status":"publish","type":"product","link":"https:\/\/cpxzx.com\/nl\/product\/cf1200-cross-fluted-film-fill-2\/","title":{"rendered":"CF1200 Cross-Fluted Film Fill for Cooling Tower"},"content":{"rendered":"<p><strong>CF1200 Cross-Fluted Film Fill<\/strong> is specifically developed for factory-assembled counterflow cooling towers used in HVAC and light industrial systems. It enhances water distribution by splitting the descending water stream, which promotes better thermal mixing and improves cooling performance. Designed for systems with low total suspended solids, CF1200 can also serve as a distribution pad in 3.9\u201d (100 mm) and 5.9\u201d (150 mm) thicknesses. The structured fill geometry splits the water stream ten times across an 11.8-inch (300 mm) vertical path, providing a strong balance of high thermal efficiency and low pressure drop.&#10;&#10;CF1200 fill utilizes an engineered cross-fluted design that maximizes heat transfer by combining precise flute angles with optimized microstructure. Manufactured under strict quality standards, this fill delivers consistent and reliable performance over extended operational periods.&#10;<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<caption><strong>Key Benefits of CF1200 Fill<\/strong><\/caption>\n<p>&#10;<\/p>\n<thead>&#10;<\/p>\n<tr>&#10;<\/p>\n<th>Benefit<\/th>\n<p>&#10;<\/p>\n<th>Beschrijving<\/th>\n<p>&#10;<\/tr>\n<p>&#10;<\/thead>\n<p>&#10;<\/p>\n<tbody>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>CTI Standard 136 Compliant<\/td>\n<p>&#10;<\/p>\n<td>Available in materials that meet Cooling Technology Institute Standard 136.<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>AccuShield Technology<\/td>\n<p>&#10;<\/p>\n<td>Optional protective coating enhances durability and chemical resistance.<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Mechanical Assembly<\/td>\n<p>&#10;<\/p>\n<td>Assembled using advanced techniques that deliver 50% stronger connections compared to glued fills.<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/tbody>\n<p>&#10;<\/table>\n<p>&#10;&nbsp;&#10;<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<caption><strong>CF1200 Design Features<\/strong><\/caption>\n<p>&#10;<\/p>\n<thead>&#10;<\/p>\n<tr>&#10;<\/p>\n<th>Functie<\/th>\n<p>&#10;<\/p>\n<th>Beschrijving<\/th>\n<p>&#10;<\/tr>\n<p>&#10;<\/thead>\n<p>&#10;<\/p>\n<tbody>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>High Thermal Efficiency<\/td>\n<p>&#10;<\/p>\n<td>Cross-fluted film design delivers superior heat transfer and enhances tower cooling capacity.<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Enhanced Water Distribution<\/td>\n<p>&#10;<\/p>\n<td>Engineered microstructure improves uniform water flow and thermal contact surface.<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Bonded Contact Points<\/td>\n<p>&#10;<\/p>\n<td>Structural bonding increases media integrity and long-term performance.<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Beveled Edge Design<\/td>\n<p>&#10;<\/p>\n<td>Beveled flute tips facilitate better drainage between fill packs, minimizing water retention.<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/tbody>\n<p>&#10;<\/table>\n<p>&#10;&nbsp;&#10;<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<caption><strong>CF1200 Technical Specifications<\/strong><\/caption>\n<p>&#10;<\/p>\n<thead>&#10;<\/p>\n<tr>&#10;<\/p>\n<th>Parameter<\/th>\n<p>&#10;<\/p>\n<th>Waarde<\/th>\n<p>&#10;<\/tr>\n<p>&#10;<\/thead>\n<p>&#10;<\/p>\n<tbody>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Oppervlakte<\/td>\n<p>&#10;<\/p>\n<td>69 ft\u00b2\/ft\u00b3<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Sheet Spacing<\/td>\n<p>&#10;<\/p>\n<td>0.46 inches<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Flute Angle<\/td>\n<p>&#10;<\/p>\n<td>30\u00b0<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Sheets per Foot<\/td>\n<p>&#10;<\/p>\n<td>26<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Minimum Pack Size (D\/W\/L)<\/td>\n<p>&#10;<\/p>\n<td>3.9&#8243; \/ 6&#8243; \/ 12&#8243;<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Maximum Pack Size (D\/W\/L)<\/td>\n<p>&#10;<\/p>\n<td>11.8&#8243; \/ 12&#8243; \/ 120&#8243;<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Standard Pack Sizes (D\/W\/L)<\/td>\n<p>&#10;<\/p>\n<td>11.8&#8243; \/ 12&#8243; \/ 48&#8243;, 72&#8243;, 96&#8243;, 120&#8243;<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Nominal Gauge<\/td>\n<p>&#10;<\/p>\n<td>8, 10, 15 mils<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/p>\n<tr>&#10;<\/p>\n<td>Dry Weight<\/td>\n<p>&#10;<\/p>\n<td>2.3, 2.7, 3.8 lbs\/ft\u00b3<\/td>\n<p>&#10;<\/tr>\n<p>&#10;<\/tbody>\n<p>&#10;<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/cpxzx.com\/wp-content\/uploads\/mbbr\/2025\/07\/CF1200-Cross-Fluted-Film-Fill.jpg\" alt=\"CF1200 Cross-Fluted Film Fill for Cooling Tower\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>CF1200 Cross-Fluted Film Fill is specifically developed for factory-assembled counterflow cooling towers used in HVAC and light industrial systems. It enhances water distribution by splitting the descending water stream, which promotes better thermal mixing and improves cooling performance. Designed for systems with low total suspended solids, CF1200 can also serve as a distribution pad in&#8230;<\/p>","protected":false},"featured_media":3807,"parent":0,"template":"","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":""},"pcategory":[5],"ptag":[],"class_list":["post-3808","product","type-product","status-publish","has-post-thumbnail","hentry","pcategory-cooling-tower-fill"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>CF1200 Cross-Fluted Film Fill for Cooling Tower - Cooling Tower Fill, China PVC Fills Manufacturer<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cpxzx.com\/nl\/product\/cf1200-cross-fluted-film-fill-2\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"CF1200 Cross-Fluted Film Fill for Cooling Tower - Cooling Tower Fill, China PVC Fills Manufacturer\" \/>\n<meta property=\"og:description\" content=\"CF1200 Cross-Fluted Film Fill is specifically developed for factory-assembled counterflow cooling towers used in HVAC and light industrial systems. It enhances water distribution by splitting the descending water stream, which promotes better thermal mixing and improves cooling performance. Designed for systems with low total suspended solids, CF1200 can also serve as a distribution pad in...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cpxzx.com\/nl\/product\/cf1200-cross-fluted-film-fill-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Cooling Tower Fill, China PVC Fills Manufacturer\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cpxzx.com\/wp-content\/uploads\/2026\/09\/CF1200-Cross-Fluted-Film-Fill.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"750\" \/>\n\t<meta property=\"og:image:height\" content=\"750\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minuut\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/cpxzx.com\\\/product\\\/cf1200-cross-fluted-film-fill-2\\\/\",\"url\":\"https:\\\/\\\/cpxzx.com\\\/product\\\/cf1200-cross-fluted-film-fill-2\\\/\",\"name\":\"CF1200 Cross-Fluted Film Fill for Cooling Tower - Cooling Tower Fill, China PVC Fills Manufacturer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cpxzx.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/cpxzx.com\\\/product\\\/cf1200-cross-fluted-film-fill-2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/cpxzx.com\\\/product\\\/cf1200-cross-fluted-film-fill-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cpxzx.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/CF1200-Cross-Fluted-Film-Fill.jpg\",\"datePublished\":\"2026-11-22T01:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/cpxzx.com\\\/product\\\/cf1200-cross-fluted-film-fill-2\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/cpxzx.com\\\/product\\\/cf1200-cross-fluted-film-fill-2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/cpxzx.com\\\/product\\\/cf1200-cross-fluted-film-fill-2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/cpxzx.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/CF1200-Cross-Fluted-Film-Fill.jpg\",\"contentUrl\":\"https:\\\/\\\/cpxzx.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/CF1200-Cross-Fluted-Film-Fill.jpg\",\"width\":750,\"height\":750},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/cpxzx.com\\\/product\\\/cf1200-cross-fluted-film-fill-2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/cpxzx.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Cooling Tower Fill\",\"item\":\"https:\\\/\\\/cpxzx.com\\\/pcategory\\\/cooling-tower-fill\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"CF1200 Cross-Fluted Film Fill for Cooling Tower\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/cpxzx.com\\\/#website\",\"url\":\"https:\\\/\\\/cpxzx.com\\\/\",\"name\":\"Cooling Tower Fill, China PVC Fills Manufacturer\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/cpxzx.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/cpxzx.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/cpxzx.com\\\/#organization\",\"name\":\"Cooling Tower Fill, China PVC Fills Manufacturer\",\"url\":\"https:\\\/\\\/cpxzx.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/cpxzx.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/cpxzx.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/1751628807-logo.png\",\"contentUrl\":\"https:\\\/\\\/cpxzx.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/1751628807-logo.png\",\"width\":383,\"height\":87,\"caption\":\"Cooling Tower Fill, China PVC Fills Manufacturer\"},\"image\":{\"@id\":\"https:\\\/\\\/cpxzx.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"CF1200 Cross-Fluted Film Fill for Cooling Tower - Cooling Tower Fill, China PVC Fills Manufacturer","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cpxzx.com\/nl\/product\/cf1200-cross-fluted-film-fill-2\/","og_locale":"nl_NL","og_type":"article","og_title":"CF1200 Cross-Fluted Film Fill for Cooling Tower - Cooling Tower Fill, China PVC Fills Manufacturer","og_description":"CF1200 Cross-Fluted Film Fill is specifically developed for factory-assembled counterflow cooling towers used in HVAC and light industrial systems. It enhances water distribution by splitting the descending water stream, which promotes better thermal mixing and improves cooling performance. Designed for systems with low total suspended solids, CF1200 can also serve as a distribution pad in...","og_url":"https:\/\/cpxzx.com\/nl\/product\/cf1200-cross-fluted-film-fill-2\/","og_site_name":"Cooling Tower Fill, China PVC Fills Manufacturer","og_image":[{"width":750,"height":750,"url":"https:\/\/cpxzx.com\/wp-content\/uploads\/2026\/09\/CF1200-Cross-Fluted-Film-Fill.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"1 minuut"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/cpxzx.com\/product\/cf1200-cross-fluted-film-fill-2\/","url":"https:\/\/cpxzx.com\/product\/cf1200-cross-fluted-film-fill-2\/","name":"CF1200 Cross-Fluted Film Fill for Cooling Tower - Cooling Tower Fill, China PVC Fills Manufacturer","isPartOf":{"@id":"https:\/\/cpxzx.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cpxzx.com\/product\/cf1200-cross-fluted-film-fill-2\/#primaryimage"},"image":{"@id":"https:\/\/cpxzx.com\/product\/cf1200-cross-fluted-film-fill-2\/#primaryimage"},"thumbnailUrl":"https:\/\/cpxzx.com\/wp-content\/uploads\/2026\/09\/CF1200-Cross-Fluted-Film-Fill.jpg","datePublished":"2026-11-22T01:00:00+00:00","breadcrumb":{"@id":"https:\/\/cpxzx.com\/product\/cf1200-cross-fluted-film-fill-2\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cpxzx.com\/product\/cf1200-cross-fluted-film-fill-2\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/cpxzx.com\/product\/cf1200-cross-fluted-film-fill-2\/#primaryimage","url":"https:\/\/cpxzx.com\/wp-content\/uploads\/2026\/09\/CF1200-Cross-Fluted-Film-Fill.jpg","contentUrl":"https:\/\/cpxzx.com\/wp-content\/uploads\/2026\/09\/CF1200-Cross-Fluted-Film-Fill.jpg","width":750,"height":750},{"@type":"BreadcrumbList","@id":"https:\/\/cpxzx.com\/product\/cf1200-cross-fluted-film-fill-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cpxzx.com\/"},{"@type":"ListItem","position":2,"name":"Cooling Tower Fill","item":"https:\/\/cpxzx.com\/pcategory\/cooling-tower-fill\/"},{"@type":"ListItem","position":3,"name":"CF1200 Cross-Fluted Film Fill for Cooling Tower"}]},{"@type":"WebSite","@id":"https:\/\/cpxzx.com\/#website","url":"https:\/\/cpxzx.com\/","name":"Koeltoren vullen, China PVC vullingen Fabrikant","description":"","publisher":{"@id":"https:\/\/cpxzx.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cpxzx.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/cpxzx.com\/#organization","name":"Koeltoren vullen, China PVC vullingen Fabrikant","url":"https:\/\/cpxzx.com\/","logo":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/cpxzx.com\/#\/schema\/logo\/image\/","url":"https:\/\/cpxzx.com\/wp-content\/uploads\/2025\/07\/1751628807-logo.png","contentUrl":"https:\/\/cpxzx.com\/wp-content\/uploads\/2025\/07\/1751628807-logo.png","width":383,"height":87,"caption":"Cooling Tower Fill, China PVC Fills Manufacturer"},"image":{"@id":"https:\/\/cpxzx.com\/#\/schema\/logo\/image\/"}}]}},"taxonomy_info":{"pcategory":[{"value":5,"label":"Cooling Tower Fill"}]},"featured_image_src_large":["https:\/\/cpxzx.com\/wp-content\/uploads\/2026\/09\/CF1200-Cross-Fluted-Film-Fill.jpg",750,750,false],"author_info":[],"comment_info":"","_links":{"self":[{"href":"https:\/\/cpxzx.com\/nl\/wp-json\/wp\/v2\/product\/3808","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cpxzx.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cpxzx.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cpxzx.com\/nl\/wp-json\/wp\/v2\/media\/3807"}],"wp:attachment":[{"href":"https:\/\/cpxzx.com\/nl\/wp-json\/wp\/v2\/media?parent=3808"}],"wp:term":[{"taxonomy":"pcategory","embeddable":true,"href":"https:\/\/cpxzx.com\/nl\/wp-json\/wp\/v2\/pcategory?post=3808"},{"taxonomy":"ptag","embeddable":true,"href":"https:\/\/cpxzx.com\/nl\/wp-json\/wp\/v2\/ptag?post=3808"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}