الصفحة الرئيسية / مزيل انجراف برج التبريد / DE080 Drift Eliminator – PVC Blade Solution for Cooling Tower Drift Control

DE080 Drift Eliminator – PVC Blade Solution for Cooling Tower Drift Control

DE080 Drift Eliminator modules are engineered to deliver superior drift droplet removal performance in cooling tower systems. These modules use a tightly spaced series of sinusoidal-shaped PVC blades, which force the air to change direction three times before exiting the tower. This unique airflow path ensures that water droplets are effectively separated from the air…

DE080 Drift Eliminator modules are engineered to deliver superior drift droplet removal performance in cooling tower systems. These modules use a tightly spaced series of sinusoidal-shaped PVC blades, which force the air to change direction three times before exiting the tower. This unique airflow path ensures that water droplets are effectively separated from the air stream. The DE080 Drift Eliminator achieves exceptional drift removal without increasing fan energy consumption. Thanks to the optimized aerodynamic structure, it maintains a very low pressure drop. This design provides a tested drift loss rate as low as 0.002% of the circulating water flow, based on CTI-HBIK Standard 140. One of the major advantages of the DE080 Drift Eliminator is its lightweight yet durable construction. The blades are held together by one-piece end caps, forming a strong module capable of spanning up to 6 feet (1.8 meters) between supports. This not only saves on material and labor costs but also reduces airflow blockage, improving the overall system efficiency. Key Features of the DE080 Drift Eliminator:

  • Easy on-site assembly reduces shipping and handling costs.
  • Frequently chosen for international projects because unassembled components ship more efficiently.
  • Designed to nest with adjacent modules, eliminating gaps that could allow drift droplet bypass.
  • Open drainage design ideal for crossflow induced draft applications.
  • Extremely low drift loss at just 0.002% of circulating water flow.
  • Available in UV-stabilized PVC or HPVC materials for high-temperature environments.
  • Material options meet CTI Standard 136 requirements.

Performance and Materials The DE080 Drift Eliminator is ideal for both counterflow and crossflow cooling towers. Its compatibility with evaporative cooling systems and scrubbers makes it a versatile solution. The material composition offers excellent resistance to UV exposure, harsh weather, and chemical degradation, including attacks from alkalis, acids, greases, oils, and biological agents. Product Weight and Structural Capability:

Blade Thickness Dry Weight Maximum Span
25 mils (0.64 mm) 1.4 lbs/ft² (6.8 kg/m²) 6 ft (1.8 m)

Applications of DE080 Drift Eliminator The DE080 Drift Eliminator is specifically designed for cooling tower applications where minimal drift is critical. It suits both retrofit and new installations. Whether installed in a counterflow cooling tower or a crossflow unit, the DE080 Drift Eliminator performs reliably and consistently. It also supports sustainable cooling tower operation by minimizing water loss, reducing chemical treatment needs, and lowering environmental impact. Its resistance to biological and chemical attack ensures long service life and consistent performance.

اترك رسالتك